[Q32-Q56] Get 100% Passing Success With True NS0-173 Exam! [Jan-2022]

Share

Get 100% Passing Success With True NS0-173 Exam! [Jan-2022] 

Network Appliance NS0-173 PDF Questions - Exceptional Practice To Cisco and NetApp FlexPod Design Specialist

NEW QUESTION 32
A customer with a FlexPod Express configuration is currently operating Linux servers. The company wants to move to a Windows-centralized access method for the NetApp storage component.
In this scenario, which two ONTAP features must be configured? (Choose two.)

  • A. Active Directory security model
  • B. SVM with the NFS protocol enabled
  • C. SVM with the SMB protocol enabled
  • D. Workgroup security model

Answer: A,C

 

NEW QUESTION 33
You are designing a FlexPod solution that requires 32 ports running at 40 Gbps.
To satisfy this requirement, which Cisco Fabric Interconnect should you deploy?

  • A. 6248UP
  • B. 6296UP
  • C. 0
  • D. 6332-16UP

Answer: C

Explanation:
FI 6332 is a one-rack-unit (1RU) 40 Gigabit Ethernet, and FCoE switch offering up to 2.56 Tbps throughput and up to 32 ports. The switch has 32 40Gbps fixed Ethernet.

 

NEW QUESTION 34
A customer wants to configure SAN boot for its FlexPod system. The customer must consider the minimum number of FC ports to be configured on each node in the ONTAP storage solution.
In this scenario, what is the minimum number of FC ports that should be configured per storage node?

  • A. three
  • B. one
  • C. two
  • D. four

Answer: A

 

NEW QUESTION 35
Click the Exhibit button.

The total number of servers that a Cisco UCS Mini chassis supports is set to a maximum of how many hosts as shown in the exhibit?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 36
A customer wants to deploy FlexPod for a VDI solution with 10,000 users, each with 10 GB of storage allocated.
To support this configuration, which three components must be sized? (Choose three.)

  • A. the Cisco UCS servers
  • B. the 1GbE ports from user systems
  • C. the optical cable length
  • D. the NetApp AFF storage
  • E. the fabric interconnect ports

Answer: A,B,E

 

NEW QUESTION 37
You are configuring Cisco UCS servers for FC SAN boot and want to perform zoning on your Cisco Nexus 5000 series switches.
In this scenario, which statement is correct?

  • A. An iSCSI license on the NetApp storage controller is required.
  • B. The corresponding FC ports on your NetApp storage array must be configured in LACP mode.
  • C. FC zoning on the Nexus series switches is not supported; zoning can be done only on the Cisco Fabric Interconnects.
  • D. SAN links are required between the Cisco Fabric Interconnects and the Nexus 5000 switches.

Answer: C

 

NEW QUESTION 38
You are asked to design a FlexPod solution with a Cisco UCS B-Series chassis. There is no requirement for any Cisco UCS C-Series rack servers. You must ensure that there is a minimum of a 2500 VLAN or VSAN capacity per UCS domain.
In this scenario, which Cisco Fabric Interconnects do you select?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

 

NEW QUESTION 39
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)

  • A. Cluster mode
  • B. Multipath mode
  • C. DualWire Management mode
  • D. Direct Connect mode
  • E. SingleConnect mode

Answer: C,D,E

Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack- Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C- Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series- Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

 

NEW QUESTION 40
A customer wants to deploy a performance-sensitive workload while leveraging NetApp Snapshot technology and technologies such as NAS and SAN.
Which architecture satisfies these requirements?

  • A. NetApp EF-Series
  • B. NetApp StorageGRID
  • C. NetApp SolidFire
  • D. NetApp AFF

Answer: C

 

NEW QUESTION 41
A client has a requirement to set up a FlexPod Datacenter with the NetApp fabric MetroCluster architecture. You want to enable connectivity between the deployments.
In this design, which two components are required to accomplish this task? (Choose two.)

  • A. Cisco MDS 9300 switches
  • B. Cisco Nexus 9000 switches
  • C. Cisco Nexus 7000 switches
  • D. Cisco Nexus 3000 switches

Answer: B,C

 

NEW QUESTION 42
A FlexPod administrator is building a WWN pool for a server that has 33 ports.
In this scenario, what is the smallest size possible for the pool?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 43
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?

  • A. 2204XP.
  • B. 0
  • C. 2208XP
  • D. 1

Answer: A

Explanation:
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that connect the blade chassis to the fabric interconnect.

 

NEW QUESTION 44
Click the Exhibit button.

You are designing a FlexPod Datacenter solution for Microsoft Windows 2012 with Hyper-V. All hosts will boot from the SAN, including management hosts. The management hosts are Cisco C-Series servers.
Referring to the exhibit, which adapters are required to boot the management servers from the SAN?

  • A. two 1GbE NICs
  • B. two 8Gb HBAs
  • C. two 10GbE NICs
  • D. two 10GbE CNAs

Answer: C

 

NEW QUESTION 45
You want to deploy a FlexPod Datacenter solution based on the minimum hardware requirements.
Which three components must be deployed in highly available pairs to accomplish this task? (Choose three.)

  • A. NetApp FAS Storage Controllers
  • B. Cisco APICs
  • C. Cisco UCS Fabric Interconnects
  • D. Cisco UCS 5108 Chassis
  • E. Cisco USC Nexus Switches

Answer: A,C,D

 

NEW QUESTION 46
You are designing a FlexPod solution with a 2-node storage system, multiple compute chassis, and ACI.
In this scenario, which two network switches are required? (Choose two.)

  • A. leaf switch
  • B. core switch
  • C. cluster interconnect switch
  • D. spine switch

Answer: A,D

 

NEW QUESTION 47
Which port type would you configure when you connect a chassis to the Cisco Fabric Interconnects?

  • A. server ports
  • B. FC storage ports
  • C. appliance ports
  • D. Ethernet uplink ports

Answer: B

 

NEW QUESTION 48
A customer wants to design a FlexPod configuration based on a CVD that was published 10 months ago. The customer wants to ensure that they are using the latest hardware and software versions.
In this scenario, which two tools are used to identify the latest supported hardware and software? (Choose two.)

  • A. Cisco UCS Hardware and Software Interoperability Matrix
  • B. Cisco UCS Director
  • C. NetApp Interoperability Matrix Tool
  • D. NetApp OnCommand System Manager

Answer: A,B

Explanation:
C: When using this matrix to determine recommended driver versions for you server configuration, please reference the server's Blade/Rack Bundle firmware version for the recommended driver in the event that your servers are running Mixed Firmware from your Infrastructure Bundle.
D: Cisco UCS Director delivers unified, highly secure management for supported compute, network, storage, and virtualization platforms and for the industry's leading converged infrastructure solutions

 

NEW QUESTION 49
A customer has installed FlexPod and verified that all wiring connections are correct. However, the customer cannot see any FC LUNs from the NetApp AFF systems.
In this scenario, which three configuration elements should the customer verify? (Choose three.)

  • A. MTU configuration
  • B. ALUA settings
  • C. igroup configuration
  • D. FC zoning
  • E. FC portsets

Answer: A,C,E

 

NEW QUESTION 50
Which Cisco Nexus series switch supports NX-OS standalone mode or Application Centric Infrastructure (ACI) fabric mode?

  • A. Nexus 9000
  • B. Nexus 5000
  • C. Nexus 3000
  • D. Nexus 7000

Answer: A

 

NEW QUESTION 51
What are characteristics of the Cisco UCS 5108 blade chassis?

  • A. 4 RU, 8 half-width UCS B-series blades, 40 Gbps I/O bandwidth
  • B. 4 RU, 6 half-width UCS B-Series blades, 160 Gbps I/O bandwidth
  • C. 6 RU, 6 half-width UCS B-series blades, 80 Gbps I/O bandwidth
  • D. 6 RU, 8 half-width UCS B-series blades, 160 Gbps I/O bandwidth

Answer: D

 

NEW QUESTION 52
A client has a FlexPod Datacenter solution with four active fabric links in port channel mode established between the Cisco Fabric Interconnects and the IOMs on a Cisco 5108 blade chassis. The blade chassis is fully populated with Cisco UCS B200M5 blades. A worker in the data center inadvertently unplugs the fourth uplink cable from IOM-A while working in the rack.
In this scenario, what happens to the network traffic?

  • A. Connectivity for servers 3, 4, 7, and 8 all fail over to IOM-B.
  • B. There is a loss of connectivity for servers 4 and 8.
  • C. Traffic is load-balanced within IOM-B.
  • D. Traffic is load-balanced within IOM-A.

Answer: A

 

NEW QUESTION 53
A customer has several existing standalone Cisco UCS C-Series servers that they would like to repurpose and add to their FlexPod Datacenter solution.
Which action should the customer perform on these servers before using UCS Manager?

  • A. Reset the CIMC to the factory settings on each server.
  • B. Remove the hard disks on each server.
  • C. Reboot the CIMC on each server.
  • D. Zero-out the FlexFlash cards on each server.

Answer: A

Explanation:
On rare occasions, such as an issue with the current running firmware, troubleshooting a server may require you to reset the CIMC to the factory default. When this happens, all user-configurable settings are reset. This procedure is not part of the normal server maintenance. After you reset the CIMC, you are logged off and must log in again. You may also lose connectivity and may need to reconfigure the network settings.

 

NEW QUESTION 54
A customer has ordered a FlexPod Select solution with a NetApp EF570.
In this scenario, which three storage protocols are available for use? (Choose three.)

  • A. FC
  • B. CIFS
  • C. NFS
  • D. InfiniBand
  • E. iSCSI

Answer: A,B,C

 

NEW QUESTION 55
Your customer has a FlexPod solution with a 2-node switchless ONTAP system, Cisco Nexus 93108 switches, and Cisco UCS B-Series servers. The customer wants to expand to a 4-node ONTAP storage cluster.
Which configuration is valid for expansion?

  • A. Use the existing Nexus 93108 switches for the cluster interconnect.
  • B. Add two Nexus 3232C switches for the cluster interconnect.
  • C. Add two Nexus 93108 switches for the cluster interconnect.
  • D. Add one Nexus 3232C switch for the cluster interconnect.

Answer: B

 

NEW QUESTION 56
......


Network Appliance NS0-173 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Virtualization Hypervisor Solutions, SAN Boot
Topic 2
  • Storage Hardware components, Configuration, High availability, SAN Boot
Topic 3
  • Compute Hardware components, Configuration, High availability, SAN Boot, UCS Manager
Topic 4
  • Networking Hardware components, Configuration, High availability, SAN Boot

 

NS0-173 dumps - PremiumVCEDump - 100% Passing Guarantee: https://www.premiumvcedump.com/NetworkAppliance/valid-NS0-173-premium-vce-exam-dumps.html