Latest HPE2-T37 Study Guides 2025 - With Test Engine PDF
Get New HPE2-T37 Practice Test Questions Answers
HP HPE2-T37 (Using HPE OneView) Certification Exam is a 60-minute exam that consists of 40 multiple-choice and multiple-response questions. HPE2-T37 exam is available in English and Japanese languages and can be taken at Pearson VUE test centers or online. The passing score for HPE2-T37 exam is 65%, and the exam fee is $150.
What are the prerequisites for taking the HPE2-T37 Exam?
Evidently, the HPE2-T37 exam is not available to candidates who have not completed their Bachelor's degree or equivalent. The qualification of the candidates who wish to take the HPE2-T37 exam is also a must. HPE2-T37 Dumps will provide you with the right guidance. In addition, It is also important for the candidates to have some prior experience in the areas of information technology. For example, they must have at least two years of experience in designing and configuring the HPE OneView Management Suite (HPE1VM) and at least two years of experience in deploying an HPE environment. The candidate should also be familiar with the HPE Hybrid IT product portfolio.
HPE2-T37 exam covers a range of topics related to HPE OneView, including the installation and configuration of the solution, the use of HPE OneView to manage infrastructure resources, the creation and management of server profiles, and the monitoring and troubleshooting of HPE OneView. HPE2-T37 exam is intended for IT professionals who are responsible for managing and maintaining infrastructure resources in a datacenter environment, including systems administrators, network administrators, and storage administrators. Passing the HPE2-T37 exam is a great way to demonstrate your expertise in using HPE OneView and advance your career in IT infrastructure management.
NEW QUESTION # 65
You originally configured boot mode for HPE ProLiant Gen10 server to 'Legacy BIOS' in an HPE OneView server profile and deployed an operating system. A few weeks later, you change the boot mode to the 'UEFI optimized' to leverage some features provided by this mode.
What must you do next?
- A. reset BIOS settings to the defaults through the server profile after changing the boot mode
- B. reinstall an operating system, as UEFI is using different drive format than Legacy BIOS
- C. reset an il_0 management processor to activate the new boot mode for the server
- D. reset BIOS settings to the defaults so UEFI settings can be applied
Answer: C
NEW QUESTION # 66
HOTSPOT
Click the option that will prevent the appliance from sending any email notifications or forwarding any SNMP traps that are related to the server hardware.
Answer:
Explanation:
Explanation:
Graphical user interface, application
Description automatically generated
NEW QUESTION # 67
For each feature. indicate whether it is available with both hpe oneview Standard and hpe oneview Advanced licenses, or only with an hpe oneview Advanced license.
Answer:
Explanation:
NEW QUESTION # 68
Within HPE OneView you can configure SNMPv1 read community string.
What is the purpose of this feature?
- A. This is an SNMP community string that will be used when traps are forwarded to other SNMP applications
- B. This is an SNMP community string that will be used when traps are forwarded to a WBEM Provider
- C. This is an SNMP community string that will be used to receive traps from HPE Onboard Administrators
- D. This is an SNMP community string that will be used to receive a trap's SNMP Agent
Answer: A
Explanation:
Reference: https://www.dnsstuff.com/snmp-community-string
NEW QUESTION # 69
Your customer wants to make sure that that each server profiles have only volume defined in the server profile template. When the customer added an extra volume to one of the server profiles, there is no report of inconsistency.
What should be verified?
- A. FC network definition and association with fabrics from SAN manager.
- B. Proper array and storage pools licensing in HPE OneView.
- C. State of the SAN connections in the server profile.
- D. Consistency checking level for SAN storage in the server profile.
Answer: D
Explanation:
The customer should verify the consistency checking level for SAN storage in the server profile. In HPE OneView, server profile templates have settings that define whether differences in storage configurations between the template and the server profiles are considered inconsistencies. If the consistency checking for SAN storage is not enabled or set to a relaxed level, adding an extra volume to a server profile may not trigger an inconsistency report.
* Option C (Correct): Ensuring that the consistency checking for SAN storage is properly configured will detect deviations.
* Option A: The state of SAN connections affects connectivity, not template compliance.
* Option B: FC network definitions are important but not directly related to template consistency checks.
* Option D: Licensing issues would prevent functionality but not affect consistency reporting.
NEW QUESTION # 70
You configured downlink aggregation for one of the HPE Synergy Compute Modules in an environment by placing two connections in the same Link Aggregation Group. After you made the changes to the server profile, its status changed to critical.
What can be done to fix this issue?
- A. The teaming or bonding driver in the server OS must be configured to enable the LACP and to form the LAG correctly.
- B. Link Aggregation Group functionality should be enabled in advanced properties of the Logical Interconnect.
- C. The server profile for a given HPE Synergy compute module should be reapplied, then the Compute Module should be rebooted.
- D. Ensure that the Link Aggregation Group time-out value matches the server set values.
Answer: B
NEW QUESTION # 71
Click the option from the HPE OneView main menu that will allow you to define UPS or other components that will work as a placeholder in a rack system.
Answer:
Explanation:
NEW QUESTION # 72
Refer to the exhibit.
Your customer wants to define a Logical Interconnect Group (UG) and set the redundancy of the master modules to highly available, but this option is not available. What is a possible reason?
- A. A dedicated license must be added to HPE OneView to enable this feature.
- B. Firmware on the master modules is too low to support highly available setup.
- C. Some master modules only support a redundant setup.
- D. There are not sufficient frames for highly available setup.
Answer: C
NEW QUESTION # 73
Click the option that will allow you to update the firmware of master and satellite modules.
Answer:
Explanation:
NEW QUESTION # 74
You need to configure a ROCE network to enable lossless networking for HPE J2000 Flash Enclosure support.
Which interconnects are able to support this connection? (Select two,)
- A. HPE Virtual Connect SE 100Gb F32 Module
- B. HPE Virtual Connect SE 40Gb F8 Module
- C. HPE VirtualConnectFlexFabric 10Gb/24-Port Module
- D. HPE Synergy Virtual ConnectSE 32Gb FC Module
- E. HPE Virtual Connect FlexFabric 20/40 F8 Module
Answer: A,E
NEW QUESTION # 75
When should HPE oneView backups be created?
- A. Before and after upgrading HPE OneView to a new version.
- B. After creating a new VM on a managed hypervisor.
- C. Before removing a server profile from HPE OneView.
- D. After updating drivers on a host managed by HPE OneView.
Answer: A
Explanation:
HPE recommends creating backups before and after upgrading HPE OneView to a new version. Backing up before an upgrade ensures you have a restore point in case the upgrade encounters issues. Creating a backup after a successful upgrade captures the current state of the appliance with the new version, allowing for future recovery if needed.
* Option D (Correct): Backups should be created both before and after upgrading.
* Option A/B/C: While backups are important, these actions do not typically necessitate an immediate backup of HPE OneView.
NEW QUESTION # 76
How can your customer implement HPE OneView so that it can be used to manage an HPE ProLiant server and HPE BladeSystem?
- A. As an application running on the server with CentOS Linux system
- B. As an application running on the server with Windows system.
- C. As a physical appliance based on HPE ProLiant 360 Gen 10.
- D. As a virtual appliance running on the supported hypervisor.
Answer: D
Explanation:
Reference: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c03934110
NEW QUESTION # 77
Refer to the exhibit.
Which statement about the storage pools shown is true?
- A. Volumes created on the first storage pool cannot use data reduction technologies
- B. Both storage pools are in a managed state and can be used for volume provisioning
- C. HPE OneView can be used to configure volume replication between these pools
- D. Both storage pools have a license applied that enables management of these pools
Answer: A
NEW QUESTION # 78
You have to move a server profile from a server to the other server. What must be done prior server profile migration?
- A. Target server has to be placed in a maintenance mode.
- B. Source server has to be powered on.
- C. Source system has to be placed in a maintenance mode.
- D. Target system must be powered off.
Answer: D
Explanation:
Before moving a server profile to another server in HPE OneView, the target system must be powered off.
This is required to ensure that the profile settings, including firmware, BIOS settings, and connectivity configurations, are applied correctly without any conflicts. Powering off the target server prevents any operational disruptions and ensures a smooth transition of the server profile.
NEW QUESTION # 79
Your customer added HPE Primera to HPE OneVlew and enabled volume provisioning on all storage pools. For security reasons, the customer wants to disable volume provisioning using HPE OneView on a specific storage pool.
How can this task be completed?
- A. The storage pool should be disabled using the array management tool.
- B. The storage pool state should be changed to discovered using HPE OneView.
- C. The storage pool should be marked as read-only using HPE OneView.
- D. The storage pool should be removed from HPE OneView using a PowerShell script.
Answer: B
NEW QUESTION # 80
......